UL Online Certifications Directory

NRNT2.E117960
Switches, Industrial Control - Component

Page Bottom


Switches, Industrial Control - Component


See General Information for Switches, Industrial Control - Component

KUN HUNG ELECTRIC CO LTD E117960
113-4 CHANGAN-DONG
DONGDAEMOON-KU
SEOUL, 130-104 REPUBLIC OF KOREA

Investigated to ANSI/UL 508

Electromechanical switches Model(s) KSD, followed by A, B, 2B or AB, maybe followed by H, V or C.

Limit switches, for use in industrial control applications Model(s) KH-8010, may be followed by -S, -C, -R, -PR, -SR, -SLR, -L(A.B.C.D.), may be followed by -L.

KH-8010-RP+, KH-8010-V1+

KL Series, followed by blank or 01, followed by CA2, CA2-2, CA12, CA12-2, CL, CL-2, CA32-41, CA32-42, CA32-43, CA32-44, D, D2, D28, D3, SD2, NJ or NJ-A2, followed by blank, T, A or M, followed by blank, LE or LD, may be followed by blank, 2 or 3, may be followed by blank, TH or TC, may be followed by blank, SA, SS, S50 or SA50, may be followed by blank or SC-A6SW

Magnetic switches Model(s) KH-102, followed by -2C or -3C, followed by blank or L

KH-103-1C*, KH-103-2C*, KH-103-3C*, KH-103-4C*, KH-103-H2C*, KH-105

Open type cam switches for use in industrial control applications Model(s) KCR-303, followed by number 2 to 12, followed by number 1 to 10, followed by number 01 to 99, followed by R, H, P or F, followed by PL or blank.

Open type illuminated push buttons for use in industrial control applications Model(s) KBL, followed by 25 or 30, may be followed by W, followed by M, MP, AT, AP, EA, EM, ER, or EP, followed by Blank or L, followed by 1A, 2A, 3A, 1C, 2C, 3C, 125D, may be followed by R, G, Y, B, or W, may be followed by any two numbers.

Open type manual electronic timers Model(s) KTM-1S

Open type manual switches, for use in industrial control applications Model(s) KH, followed by -22, -25 or -30, followed by 01, followed by SL, followed by -0, -1, or -2, followed by 0, 1, or 2, followed by R, G, Y, W, B or O.

KH-2201, followed by blank, S, EB, ER or AT

KH-2202-, followed by 2S, 2L, 2K, 3S, 3L, 3K, 2AS, 2AL, 2AK, 3AS, 3AL, 3AK, 3RS, 3RL or 3RK, maybe followed by -1 or -2, maybe followed by 1 or 2

KH-2204, followed by blank or L, followed by blank, EB, ER, P or AT, followed by -1, -2, -3 or -TL

NF30-, followed by L, P, B, S or K, followed by M, A, 2S, 3S, A2S, A3S, 3RS, 2L, 3L, A2L, A3L, 3RL, 2K, 3K, A2K, A3K, 3RK or Blank, maybe followed by 1A, 2A, 3A, 1C, 2C or 3C, maybe followed by R, G, Y, W, B or O, maybe followed by 1 or 2, maybe followed by 1 or 2

Open type push buttons for use in industrial control applications Model(s) KPB or KEPB, followed by 22, 25 or 30, may be followed by W, followed by M,MS, ML, AT, EM, EA, ER, or EP, may be followed by S, may be followed by R, G, Y, B, W or BK,may be followed by any two numbers

Open type selector switches for use in industrial control applications Model(s) KSL, followed by 25 or 30, may be followed by W, may be followed by S2, L2, S3, L3, AL2, AS2, AS3 RS3, RL3, K2, AK2, K3, AK3 or RK3 may be followed by additional numbers

Open type switches, for use in industrial control applications Model(s) KH-9012-, followed by blank or 5, followed by PB, PBF, HL, HLL, HLR, HRL, HRM or HRS, followed by B or C

KH-9015-, followed by PBF, PBL, PBS, RP, CRP, HL, HLL, HRL, HRM, HRS, HRSH, HRSW, HLZ or HP

KH-9115-, followed by HRS

Type NF, followed by 25 or 30, followed by G or Blank, followed by W or Blank, followed by -L, -P, -B, -S or -K, followed by 2, 3, A2, A3 or 3R, maybe followed by 1A, 2A, 1C, 2C or 3C, maybe followed by R, G, Y, W, B or O, maybe followed by 1 or 2, maybe followed by 1 or 2

Type NF, followed by 25 or 30, followed by G or Blank, followed by W or Blank, followed by -L, -P, -B, -S or -K, followed by M, A, EM, EA or ER, maybe followed by 1A, 2A, 1C, 2C or 3C, maybe followed by R, G, Y, W, B or O, maybe followed by 1 or 2, maybe followed by 1 or 2

Type NF, followed by 25 or 30, followed by G or Blank, followed by W or Blank, followed by -L, followed by 1A, 2A, 1C, 2C or 3C

Investigated to

Industrial Control Switches Model(s) KBL followed by 25 or 30, may be followed by W, followed by M, MP, AT, AP, EA, EM, ER, or EP, followed by Blank or L, followed by 1A, 2A, 3A, 1C, 2C, 3C, 125D, may be followed by R, G, Y, B, or W, may be followed by any two numbers.

KCR-303 followed by number 2 to 12, followed by number 1 to 10, followed by number 01 to 99, followed by R, H, P or F, followed by PL or blank.

KH followed by -22, -25 or -30, followed by 01, followed by SL, followed by -0, -1, or -2, followed by 0, 1, or 2, followed by R, G, Y, W, B or O.

KH-102 followed by -2C or -3C, followed by blank or L

KH-2202- followed by 2S, 2L, 2K, 3S, 3L, 3K, 2AS, 2AL, 2AK, 3AS, 3AL, 3AK, 3RS, 3RL or 3RK, maybe followed by -1 or -2, maybe followed by 1 or 2

KH-2204 followed by blank or L, followed by blank, EB, ER, P or AT, followed by -1, -2, -3 or -TL

KH-8010, may be followed by -S, -C, -R, -PR, -SR, -SLR, -L(A.B.C.D.), may be followed by -L.

KH-9012- followed by blank or 5, followed by PB, PBF, HL, HLL, HLR, HRL, HRM or HRS, followed by B or C

KH-9015- followed by PBF, PBL, PBS, RP, CRP, HL, HLL, HRL, HRM, HRS, HRSH, HRSW, HLZ or HP

KL Series followed by blank or 01, followed by CA2, CA2-2, CA12, CA12-2, CL, CL-2, CA32-41, CA32-42, CA32-43, CA32-44, D, D2, D28, D3, SD2, NJ or NJ-A2, followed by blank, T, A or M, followed by blank, LE or LD, may be followed by blank, 2 or 3, may be followed by blank, TH or TC, may be followed by blank, SA, SS, S50 or SA50, may be followed by blank or SC-A6SW

KPB or KEPB followed by 22, 25 or 30, may be followed by W, followed by M,MS, ML, AT, EM, EA, ER, or EP, may be followed by S, may be followed by R, G, Y, B, W or BK,may be followed by by any two numbers

KSD followed by A, B, 2B or AB, maybe followed by H, V or C.

KSL followed by 25 or 30, may be followed by W, may be followed by S2, L2, S3, L3, AL2, AS2, AS3 RS3, RL3, K2, AK2, K3, AK3 or RK3 may be followed by additional numbers

NF30- followed by L, P, B, S or K, followed by M, A, 2S, 3S, A2S, A3S, 3RS, 2L, 3L, A2L, A3L, 3RL, 2K, 3K, A2K, A3K, 3RK or Blank, maybe followed by 1A, 2A, 3A, 1C, 2C or 3C, maybe followed by R, G, Y, W, B or O, maybe followed by 1 or 2, maybe followed by 1 or 2

* - With suffix P or blank, followed by L or blank.

+ - May be followed by additional numbers or letters.


Marking: Company name or tradename "Koino + KUN HUNG" and model designation on the product or on the smallest unit container in which the product is packaged.
Last Updated on 2017-06-10
NRNT2.E117960 E117960 NRNT2 376578001 Listing Active 20170610 20170610

Questions?

Print this page

Terms of Use

Page Top

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2017 UL LLC".